1
Record the rated parameters in the computer screen, check before the next startup, if found different, please enter according to the recorded data.

2
After powering off, clean up the dust on the electrical components inside the electric control box, focus on cleaning the inverter, governor and PLC, you can use compressed air to blow inside the components, but there can be no moisture. Tighten loose cable and wire joints; Check the cable insulation. Replace aging or poorly connected components in time.

3
Check whether the main motor is refueled and whether the coupling pad is damaged. Check the gearbox for abnormal noise, and do the gearbox gear oil filling and replacement.


4
Waterway cleaning, emptying water in and out of the water system, so as not to crack the pipeline in the winter cold.


5
Protect and seal the die, and protect the roller wrap to prevent bumping.


6
Check the moving parts of each equipment for adequate lubrication. In particular, frequent operation of the lead screw, roller, bearing, guide post and other parts to prevent the temperature is too low, resulting in the moving parts stuck, thus affecting the normal production. Bearing, universal shaft, etc., need to add grease regularly.

7
Check and calibrate instruments that display pressure, current, voltage, temperature, etc.; Check the heating condition of each heating element and replace the damaged heating and sensing element.



8
Clean the filter drum filter screen of the feeding system , dust collection bag, etc.
9
After the gas supply is stopped, check that all rubber rollers are in a non-pressing state to prevent deformation of the roll surface.

10
Before starting the next time, please use a multimeter to measure whether there is short circuit between the three phase lines and the three phase line to the ground, to prevent mice from biting the wire and causing short circuit.